Brocade Network OS Command Reference v4.1.0 Manuel d'utilisateur Page 115

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 141
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 114
Network OS Command Reference 77
53-1003115-01
cidrecov
2
cidrecov
Recovers data from Chassis ID cards if possible.
Synopsis cidrecov
Operands There are no operands for this command.
Defaults None
Command Modes Privileged EXEC mode
Description Use this command if you receive an error or warning RASLog message that instructs you to run this
command.
Two chassis ID (CID) cards contain data necessary for system operation. Each CID contains two
Serial Electronically Erasable Programmable Read Only Memory (SEEPROM) devices. If data on
either card becomes corrupt or mismatched, a regularly run CID audit writes messages to the
RASLog. Follow the instructions in the messages. Mismatched data can be reset, and corrupt data
can sometimes be recovered if the corrupt data is on the non-critical SEEPROM.
Usage Guidelines This command is supported only on Brocade VDX 8770-4 and Brocade VDX 8770-8 switches.
Examples Example 1: Noncritical SEEPROM is inaccessible or corrupt, but recovery becomes possible:
sw0# cidrecov
CID 1 Non-Critical Seeprom is Inaccessible or Corrupted.
CID Non-Critical Seeprom Problem Details
CID 1 Non-Critical Seeprom IP address Control Data Checksum Bad !!!!
CID 1 IP address Control Data:
Version: 0xa
Checksum: 0x0
Size: 0x3
CID 2 IP address Control Data:
Version: 0xa
Checksum: 0x7
Size: 0x3
***WARNING: Recovering IP Data May Affect Both IP Control and IP Records ***
Backup Current Data Displayed Below If Needed.
CID 1 Chassis Name: VDX8770-4
CID 2 Chassis Name: VDX8770-4
CID 1 IP address Control Data:
Version: 0xa
Checksum: 0x0
Size: 0x3
CID 2 IP address Control Data:
Version: 0xa
Checksum: 0x7
Size: 0x3
Vue de la page 114