Multi-Service IronWare Routing Configuration Guide 309
53-1003033-02
Displaying IPv4 IS-IS information
Length Too Long The number of PDUs dropped at both Level-1 and Level-2 because the
received PDU length is greater than the MTU of the link. This counter will
only be displayed if it has a value greater than zero.
Max Area Check Failure The number of PDUs dropped at both Level-1 and Level-2 because the
received PDU has a maximum area count different than what is
configured on this IS-IS router. This counter will only be displayed if it
has a value greater than zero.
Zero Checksum The number of PDUs dropped at both Level-1 and Level-2 because the
received PDU has a zero checksum. This counter will only be displayed if
it has a value greater than zero.
Checksum Mismatch The number of PDUs dropped at both Level-1 and Level-2 because the
received PDU has a checksum different than the computed checksum
on the received PDU. This counter will only be displayed if it has a value
greater than zero.
Invalid Length The number of PDUs dropped at both Level-1 and Level-2 because the
received PDU has a different length than what is advertised in the PDU
header. This counter will only be displayed if it has a value greater than
zero.
TABLE 48 IS-IS error statistics (Continued)
This field... Displays...
Vue de la page 336