Brocade Network OS Message Reference v4.1.1 Manuel d'utilisateur Page 211

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 478
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 210
Network OS Message Reference 195
53-1003227-01
FSS-1004
8
FSS-1004
Message FSS out of memory (<memory allocation with number of bytes>).
Message Type LOG
Severity ERROR
Probable Cause Indicates that the system ran out of memory.
Recommended
Action
Check memory usage on the switch using the show process memory command.
Execute the copy support command and contact your switch service provider.
FSS-1005
Message FSS read failure.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the read system call to the fabric synchronization service (FSS) device has failed.
Recommended
Action
If the message persists, execute the copy support command and contact your switch service provider.
FSS-1006
Message No FSS message available.
Message Type LOG
Severity WARNING
Probable Cause Indicates that data is not available on the fabric synchronization service (FSS) device.
Recommended
Action
If the message persists, execute the copy support command and contact your switch service provider.
Vue de la page 210
1 2 ... 206 207 208 209 210 211 212 213 214 215 216 ... 477 478

Commentaires sur ces manuels

Pas de commentaire