Brocade Network OS Message Reference v4.1.1 Manuel d'utilisateur Page 321

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 478
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 320
Network OS Message Reference 305
53-1003227-01
NSM-1027
8
NSM-1027
Message <SFPType> transceiver for interface <InterfaceName> is removed.
Message Type DCE
Severity INFO
Probable Cause Indicates that a transceiver (SFP or CFP2) has been removed from the specified interface.
Recommended
Action
No action is required.
NSM-1028
Message Incompatible SFP transceiver for interface <InterfaceName> is detected.
Message Type DCE
Severity ERROR
Probable Cause Indicates that an incompatible small form-factor pluggable (SFP) transceiver for the interface has been
inserted.
Recommended
Action
Disable the interface using the shutdown command and insert an SFP transceiver that is supported on
the interface. After the SFP transceiver is inserted, re-enable the interface using the no shutdown
command.
NSM-1029
Message Failed to read SFP transceiver for interface <InterfaceName>.
Message Type DCE
Severity ERROR
Probable Cause Indicates failure to read the small form-factor pluggable (SFP) transceiver for the specified interface.
Recommended
Action
Disable the interface using the shutdown command and re-insert the SFP transceiver. After the SFP
transceiver is inserted, re-enable the interface using the no shutdown command. If the problem persists,
contact your switch service provider.