Vue de la page 323
308 Network OS Message Reference
53-1003227-01
NSM-1037
8
NSM-1037
Message Interface <InterfaceName> is administratively down due to 1Gbps link configured on
Brocade Trunk.
Message Type DCE
Severity INFO
Probable Cause Indicates that the specified interface has gone down because a 1 Gbps link has been configured on the
Brocade trunk.
Recommended
Action
Remove the 1 Gbps link from the Brocade trunk or change the 1 Gbps small form-factor pluggable (SFP)
transceiver.
NSM-1038
Message Private VLAN mode changed from <Mode_old> to <Mode_new> for interface
<InterfaceName>.
Message Type DCE
Severity INFO
Probable Cause Indicates that the interface private VLAN mode has been changed.
Recommended
Action
No action is required.
NSM-1039
Message Unsupported Brocade-branded SFP transceiver for interface <InterfaceName> is
detected.
Message Type DCE
Severity ERROR
Probable Cause Indicates that an unsupported Brocade-branded small form-factor pluggable (SFP) transceiver has been
inserted in the specified interface.
Recommended
Action
Use a Brocade-branded SFP transceiver for the interface because the digital diagnostics will not be
supported.