Network OS Message Reference 79
53-1003227-01
AG-1009
8
AG-1009
Message Sending FLOGI failed on N_Port <port>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that there was a failure sending a Fabric Login (FLOGI) request from the Access Gateway to
the fabric switch.
Recommended
Action
Check the configuration of the fabric switch connected to the Access Gateway.
If the message persists, execute the copy support command and contact your switch service provider.
AG-1010
Message Sending PLOGI failed on N_Port <port>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that there was a failure sending an N_Port Login (PLOGI) request from the Access Gateway to
the fabric switch.
Recommended
Action
Check the configuration of the fabric switch connected to the Access Gateway.
If the message persists, execute the copy support command and contact your switch service provider.
AG-1011
Message Sending FDISC failed on N_Port <port>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that there was a failure sending a discover VF_Port service parameter request from the Access
Gateway to the fabric switch.
Recommended
Action
Check the configuration of the fabric switch connected to the Access Gateway.
If the message persists, execute the copy support command and contact your switch service provider.