Brocade Network OS Message Reference v4.1.1 Manuel d'utilisateur Page 213

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 478
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 212
Network OS Message Reference 197
53-1003227-01
FSS-1010
8
FSS-1010
Message FSS Warning: <Warning Message>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that a fabric synchronization service (FSS) error may have occurred.
Recommended
Action
No action is required.
FSS-1011
Message All services complete the critical recoveries in <time taken for the critical
service recovery> sec.
Message Type LOG
Severity INFO
Probable Cause Indicates a non-disruptive failover with warm recovery.
Recommended
Action
If the time taken for critical service recovery is more than 8 seconds, contact your switch service provider.
FSS-1012
Message FSS transport flow hitting the threhold (<number of waiting requests>:<the current
xmb allocation size>:<total of KERNEL memory>:<total of ATOMIC memory>).
Message Type LOG | FFDC
Severity CRITICAL
Probable Cause Indicates that the underlying transport is not healthy.
Recommended
Action
Execute the copy support command and contact your switch service provider.
Vue de la page 212